Check manual page of ucs_c_rack_server_util.pci_io

Checkmk Manual

On this page

Search in the manual

UCS C-Series Rack Server: PCI IO utilization

Distribution: official part of Check_MK
License: GPL
Supported Agents: AGENT_UCS_BLADECENTER

This check provides information about the IO utilization of an UCS C-Series Rack Servers racks. The metric is an aggregation of the traffic of all PCI Express ports of a servers rack unit and has percentage as unit. The calculation of the utilization is based on an aggregation of RMCs (Resource Monitoring Counters) of a servers rack unit PCI Express Root Ports.

This check supports the following C-Series Rack Server models providing XML API 2.0 [Cisco UCS Rack-Mount Servers Cisco IMC XML API 2.0]:

- Cisco UCS C220 M5 Rack Server

- Cisco UCS C240 M5 Rack Server

- Cisco UCS C480 M5 Rack Server

- Cisco UCS C480 ML M5 Rack Server

- Cisco UCS C220 M4 Rack Server

- Cisco UCS C240 M4 Rack Server

- Cisco UCS C460 M4 Rack Server

This check does not support the C-Series Rack Server model "Cisco UCS C125 M5 Rack Server Node" which is used as part of a "Cisco UCS C4200 Series Rack Server Chassis".

Check status:

- OK in case the monitored IO utilization is within the configured valid range.

- WARN in case the monitored IO utilization is equal or higher than the configured warn level.

- CRIT in case the monitored IO utilization is equel or higher than the configured crit level.

The default value for the warn level is 90.0%. The default value for the crit level is 95.0%. The warn and crit level are configurable via WATO rule Device Component PCI IO Utilization.

Item

One item per server rack.

Discovery

All server racks included in the agent plugin output are found automatically.